<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>15085</ErrorNumber>
<ErrorFamily>Autoloader</ErrorFamily>
<ErrorMessage>
ALE: roller on drum
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_400/800</Text></ListItem>
<ListItem><Text>Trendsetter_400/800_Auto</Text></ListItem>
<ListItem><Text>Platesetter_VLF</Text></ListItem>
<ListItem><Text>Trendsetter_VLF</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
The roller is detected on the drum when a drum move command is issued.
Check for faulty roller sensors by using the "rlr" command from the diagnostic.  If the sensor is
faulty, use "set al nrs 1" or "set al rs 0" to bypass the sensor and get the customer going.
Arrange for field service.  If the sensor is OK, test the roller actuator by using "rlr on" or
"rlr off" and see if any motion occurs.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Select Resume if that option is available.  If the problem persists, turn the machine off, wait
a few seconds, then turn it back on.  Call the Creo Response Centre for assistance.
</text></DescriptionText>
</OperatorAction>
<Cause>
Invalid diagnostic command.  Move the roller off the drum before issuing drum commands.
</Cause>
<Cause>
Faulty roller sensor.  The "roller up" sensor is reading FALSE.
</Cause>
<Cause>
Faulty roller cylinder.  Try moving it manually with "rlr on" and "rlr off" commands.
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../nvs/al_cal_rs.xml</LinkAddress><LinkTitle>NVS: al rs</LinkTitle></Link>
<Link><LinkAddress>../nvs/al_cal_nrs.xml</LinkAddress><LinkTitle>NVS: al nrs</LinkTitle></Link>
<Link><LinkAddress>../commands/rlr.xml</LinkAddress><LinkTitle>Command: rlr</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:32:52 2008 PST
</Updated>
<Links>
<Link><LinkAddress>http://techplanet.creo.com/output/computer_to_plate/trendsetter_3244/content/troubleshooting/15085.html</LinkAddress><LinkTitle>Other: Troubleshooting information</LinkTitle></Link>
</Links>
</Error>